User:JuneAugust/IEC 60529

IP Code ( 侵入防护等级I ngress P rotection Rating),[1] 有时也可解释为国际保护等级I nternational P rotection Rating)[2]) of the letters IP后跟两位数字或者一个数字和一个字母和一个可选的字母。As defined in international standard IEC 60529, IP Code classifies and rates the degrees of protection provided against the intrusion of solid objects (including body parts like hands and fingers), dust, accidental contact, and water in mechanical casings and with electrical enclosures.[3]

The standard aims to provide users more detailed information than vague marketing terms such as waterproof. However, no edition of the standard is openly published for unlicensed readers.

The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X.

For example, an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. IP22 or 2X are typical minimum requirements for the design of electrical accessories for indoor use.

Code breakdown

IP Indication Solid Particle Protection Liquid Ingress Protection Mechanical impact resistance Other Protections
IP Single Number: 0-6 Single Number: 0-8 Single Number: 0-9 Single Letter
Mandatory Mandatory Mandatory No longer used Optional

固体颗粒防护

The first digit indicates the level of protection that the enclosure provides against access to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid foreign objects.

级别 防护针对对象大小 防护效果
0 没有防接触和物体侵入
1 >50 mm Any large surface of the body, such as the back of a hand, but no protection against deliberate contact with a body part
2 >12.5 mm Fingers or similar objects
3 >2.5 mm Tools, thick wires, etc.
4 >1 mm Most wires, screws, etc.
5 Dust protected 尚未彻底防尘,但其进入的数量不足以干扰设备的正常的运作;彻底防止与外物的接触
6 Dust tight 防尘;彻底防止与外物的接触

液体的防护等级

Protection of the equipment inside the enclosure against harmful ingress of water.[4]

Level Protected against Testing for Details
0 Not protected
1 Dripping water Dripping water (vertically falling drops) shall have no harmful effect. Test duration: 10 minutes

Water equivalent to 1mm rainfall per minute

2 Dripping water when tilted up to 15° Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle up to 15° from its normal position. Test duration: 10 minutes

Water equivalent to 3mm rainfall per minute

3 Spraying water Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect. Test duration: 5 minutes

Water volume: 0.7 litres per minute
Pressure: 80–100 kPa

4 Splashing water Water splashing against the enclosure from any direction shall have no harmful effect. Test duration: 5 minutes

Water volume: 10 litres per minute
Pressure: 80–100 kPa

5 Water jets Water projected by a nozzle (6.3mm) against enclosure from any direction shall have no harmful effects. Test duration: at least 3 minutes

Water volume: 12.5 litres per minute
Pressure: 30 kPa at distance of 3m

6 Powerful water jets Water projected in powerful jets (12.5mm nozzle) against the enclosure from any direction shall have no harmful effects. Test duration: at least 3 minutes

Water volume: 100 litres per minute
Pressure: 100 kPa at distance of 3m

7 Immersion up to 1 m Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1 m of submersion). Test duration: 30 minutes

Immersion at depth of 1m

8 Immersion beyond 1 m The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer. Normally, this will mean that the equipment is hermetically sealed. However, with certain types of equipment, it can mean that water can enter but only in such a manner that it produces no harmful effects. Test duration: continuous immersion in water

Depth specified by manufacturer

附加字母

The standard defines additional letters that can be appended to classify only the level of protection against access to hazardous parts by persons:

Level Protected against access to hazardous parts with
A Back of hand
B Finger
C Tool
D Wire

Further letters can be appended to provide additional information related to the protection of the device:

字母 含义
H High voltage device
M Device moving during water test
S Device standing still during water test
W Weather conditions

Mechanical impact resistance

An additional number has sometimes been used to specify the resistance of equipment to mechanical impact. This mechanical impact is identified by the energy needed to qualify a specified resistance level, which is measured in joules (J). This has now been superseded by the separate IK number specified in EN 62262.

Although dropped from the 3rd edition of IEC 60529 onwards, and not present in the EN version, older enclosure specifications will sometimes be seen with an optional third IP digit denoting impact resistance. Newer products are likely to be given an IK rating instead. However there is not an exact correspondence of values between the old and new standards.

Dropped IP level Impact energy Equivalent drop mass and height
0
1 0.225 J 150 g dropped from 15 cm
2 0.375 J 250 g dropped from 15 cm
3 0.5 J 250 g dropped from 20 cm
5 2 J 500 g dropped from 40 cm
7 6 J 1.5 kg dropped from 40 cm
9 20 J 5.0 kg dropped from 40 cm
IK
number
Impact energy
(joules)
Equivalent impact
00 Unprotected No test
01 0.15 Drop of 200 g object from 7.5 cm height
02 0.2 Drop of 200 g object from 10 cm height
03 0.35 Drop of 200 g object from 17.5 cm height
04 0.5 Drop of 200 g object from 25 cm height
05 0.7 Drop of 200 g object from 35 cm height
06 1 Drop of 500 g object from 20 cm height
07 2 Drop of 500 g object from 40 cm height
08 5 Drop of 1.7 kg object from 29.5 cm height
09 10 Drop of 5 kg object from 20 cm height
10 20 Drop of 5 kg object from 40 cm height

IPX Coding =

字母X is used in any place in the code where specifying a digit is meant to be avoided. There may be various reasons for choosing this coding variant, such as marketing considerations. Thus, e.g. an IPX7 rating for a consumer device specifies that the device has water protection up to limited immersion, but gives deliberately no information as to whether the device has any protection against mechanical ingress or dust. Among other common IP ratings using the letter X are IPX4.

IP69K

German standard DIN 40050-9 extends the IEC 60529 rating system described above with an IP69K rating for high-pressure, high-temperature wash-down applications.[5] Such enclosures must not only be dust tight (IP6X), but also able to withstand high-pressure and steam cleaning.

The test specifies a spray nozzle that is fed with 80°C water at 8–10MPa (80–100bar) and a flow rate of 14–16L/min. The nozzle is held 10–15 cm from the tested device at angles of 0°, 30°, 60° and 90° for 30s each. The test device sits on a turntable that rotates once every 12s (5rpm).

The IP69K test specification was initially developed for road vehicles, especially those that need regular intensive cleaning (dump trucks, cement mixers, etc.), but also finds use in other areas (e.g., food industry, car wash centres).

NEMA rating

IP Code Min. NEMA Enclosure rating to satisfy IP Code
IP20 1
IP54 3
IP65 4, 4X
IP67 6
IP68 6P

The United States National Electrical Manufacturers Association (NEMA) also publishes protection ratings for enclosures similar to the IP rating system published by the International Electrotechnical Commission (IEC). However, it also dictates other product features not addressed by IP codes, such as corrosion resistance, gasket aging, and construction practices. Thus, while it is possible to map IP Codes to NEMA ratings that satisfy or exceed the IP Code criteria, it is not possible to map NEMA ratings to IP codes, as the IP Code does not mandate the additional requirements. The table above indicates the minimum NEMA rating that satisfies a given IP code, but can only be used in that way, not to map IP to NEMA.[6]

North American enclosure rating systems are defined in NEMA 250, UL 50, UL 508, and CSA C22.2 N°. 94.

另见

参考

  1. ^ Interpreting the acronym officially in the standard text
  2. ^ IEC 60529 (ed2.1), clause 4.1.
  3. ^ IEC 60529: Degrees of protection provided by enclosures (IP Code). 国际电工委员会, Geneva.
  4. ^ Ingress Protection: The System of Tests and Meaning of Codes .
  5. ^ DIN 40050-9: Straßenfahrzeuge; IP-Schutzarten; Schutz gegen Fremdkörper, Wasser und Berühren; Elektrische Ausrüstung [Road vehicles; degrees of protection (IP-code); protection against foreign objects, water and impact; electrical equipment], May 1993 . An English translation of the German original is available from DIN.
  6. ^ FAQ — Enclosures. NEMA. [2010-03-03]. 

外部链接